[169]: data by Dr.Angel Lopez Castro, Madrid, Spain [254]: data by Dr.U.nsal, Izmir, Turkey Hong Kong [349]: data by Dr.Dhaval S. Modi, Ahmedabad, India [266]: data by Dr. A. Hhn, Oldenburg, Germany 2018;12:2031-2037. Proprietary Precision Edge Design3,4 Proprietary edge curvature designed to help reduce PCO and edge glare.3,4 Superior Axial Stability5,6 Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability.4-6 Optical Design with Proven Performance3,4,7,8 [38]: data by Dr.Michaela Mees, Sulzbach, Germany [131]: data by Dr.M.Rau, Furth i.W., Germany We welcome your input for improving our users Experience. Rayner Centerflex 570 H A=118.0 a0=1.04 a1=0.40 a2=0.10 pACD=5.22 sf=1.45 A=118.4 A=118.7 118 [38],[52] official website and that any information you provide is encrypted Hoya iMics1 NY-60 Hoya iSert 250/251 (+) A=118.4 a0= -0.542 a1=0.161 a2=0.204 pACD=5.30 sf=1.52 A=118.5 A=118.8 319 [81],[172],[226],[328],[81] [161]: data by Dr.K.Schneider, Mnchengladbach, Germany AMO Tecnis ZMA00 A=119.1 a0= -1.750 a1=0.242 a2=0.266 pACD=5.80 sf=2.06 A=119.5 A=120.0 205 [78],[243] [6]: based on data by different surgeons from Eye Clinic Kln-Merheim, Germany [402]: data by Dr. D. Breyer, Dsseldorf, Germany [105]: data by Wavelight AG, Berlin, Germany Jan 2002 Alcon SA60AT (Japan) A=118.4 a0= -1.627 a1=0.305 a2=0.248 pACD=5.64 sf=1.83 A=118.9 A=119.2 501 [41] Moss Vision Optiflex MO/F-013 A=118.0 a0=0.71 a1=0.40 a2=0.10 pACD=4.85 sf=1.10 A=117.9 A=118.0 50 [369] [384]: data by Prof. JOO Choun-Ki, Seaoul, South Korea Based on 2 large datasets (1: N = 888 Hoya Vivinex aberration-correcting and 2: N = 822 Alcon SA60AT spherical lens) a classical formula constant optimisation has been performed for the Hoffer Q, Holladay 1, Haigis and Castrop formulae, to minimise the root mean squared (rms) PE (situation A). Oculentis LS-505 A=118.0 a0= 1.02 a1=0.40 a2=0.10 pACD=5.17 sf=1.40 A=118.3 A=118.6 39 [170],[173] [334]: data by Dr. Humberto Carreras, Las Palmas, Spain [31]: data by Dr.H.Greber,Oberschleissheim, Germany CODE: NS010693003. [61]: data by R.Donoso, Chile R.Tumer MD(Frankfurt, Germany), [136]: data by Dr.J.Blazek, Pardubice, Czech Republic Before Oculentis LS-313 MF30 A=118.0 a0=0.95 a1=0.40 a2=0.10 pACD=5.21 sf=1.47 A=118.5 A=118.6 239 [259],[304],[311],[312],[327] [340]: data by Dr. Hanemoto, Mito, Japan [170]: data by Dr.A.Parasta, Mnchen, Germany The following table may be downloaded and fed directly into the IOLMaster. HumanOptics Torica-aA(Y) A=118.4 a0=1.18 a1=0.40 a2=0.10 pACD=5.35 sf=1.51 A=118.3 A=118.4 44 [397] [352]: data by Dr. Dale Pilkinton, Nashville, TN, USA [347]: data by Dr. Ugur Unsal, Izmir, Turkey ZEISS CT 47LC (Acri.Lyc 47LC) A=117.7 a0=0.308 a1=0.300 a2=0.133 pACD=4.96 sf=1.17 A=117.9 A=118.0 192 [213],[214] Hoya AF-1 VA-60BB A=118.7 a0=1.24 a1=0.40 a2=0.10 pACD=5.43 sf=1.65 A=118.7 A=118.9 50 [81] [402]: data by Dr. D. Breyer, Dsseldorf, Germany [389]: data by Dr. C. Dulanto, Inst. [113]: data by R.Arleo, MD, Ithaca, Ithaca, NY, USA [319]: data by Dr. Antoni Salvador Playa, Terrassa, Spain [291]: data by Dr. J. Grngreiff, Wanzleben, Germany Russia, Asia Pacific ISPAN Sulfur Hexafluoride SF6 - For use with CONSTELLATION Vision System, KELMAN MULTIFLEX III PMMA Single-Piece Anterior Chamber Lenses, (carbachol intraocular solution, USP) 0.01%, MONOFLEX PMMA EXPAND Single-Piece Series IOLs, OPTI-FREE Express Multi-Purpose Disinfecting Solution, OPTI-FREE PureMoist Multi-Purpose Disinfecting Solution, OPTI-FREE RepleniSH Multi-Purpose Disinfecting Solution, OPTI-FREE SupraClens Daily Protein Remover, SYSTANE Lubricant Eye Drops - Preservative-Free Vials (Unit Dose), SYSTANE NIGHTTIME Lubricant Eye Ointment, SYSTANE ULTRA Lubricant Eye Drops - Preservative-Free Vials (Unit Dose), Patient Information for MODELS SA6AT6, SA6AT7, SA6AT8, SA6AT9, SN6AT6, SN6AT7, SN6AT8, SN6AT9, Professional Fitting and Information Guide. please click here). [156]: data by Francis Reid, MD, Oak Ridge, TN, USA [52]: data by PD Dr.W.Sekundo, Marburg, Germany Singapore, Online Ordering for Surgical Supplies and Contact Lenses, Digital Platform Connecting You to Your Patients and Providing Hassle-Free Contact Lenses to Patients through Your Practice, THE CLAREON COLLECTION IOL: DEDICATED TO SHARP, CRISP VISION, Clareon Monofocal IOLs provide exceptional clarity*, allowing you to confidently deliver the long-lasting refractive outcomes that your monofocal patients expect.1,2, Exceptional Clarity that Lasts1Delivers among the lowest levels of glistenings, SSNGs, and surface haze.1,2, Proprietary edge curvature designed to help reduce PCO and edge glare.3,4, Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability.4-6, Optical Design with ProvenPerformance3,4,7,8, Clareon and AcrySof share the same -0.2m aspheric design resulting in improved depth of focus.7,8, New advanced manufacturing process combines a proprietary precision edge design with the exceptional BioOptics and BioMechanics of all Alcon IOLs.4. [127]: data by H.Geggle MD,Seattle, WA, USA Polytech Polylens A61 (+) A=118.2 a0=0.86 a1=0.40 a2=0.10 pACD=5.06 sf=1.29 A=118.2 A=118.4 79 [13],[29] [397]: data by Prof. Dr. Schnherr, Linz, Austria ZEISS CT ASPHINA 509M (Acri.Smart 36A) A=118.0 a0=0.68 a1=0.40 a2=0.10 pACD=4.90 sf=1.12 A=117.9 A=118.1 92 [111],[209] The lens consists of a high refractive index soft acrylic material capable of being folded prior to insertion. [93]: data by Dr.Walch/Dr.Storch, Wien, Austria [388]: data by Prof. Dr. Burkhard Dick, Bochum, Germany [169]: data by Dr.Angel Lopez Castro, Madrid, Spain [155]: data by Prof.Dr.Grabner, Salzburg, Austria [75]: data by Dr.U.Heuer, Hamburg, Germany [330]: data by Dr. Gilles Lesieur, Albi, France Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: three-year results. 2013 Dec;39(12):1886-92. doi: 10.1016/j.jcrs.2013.06.021. [287]: data by Dr. Alexander Tunas, Hamburg, Germany [224]: data by Dr.F.Bauer, Rosenheim, Germany Range . [288]: data by Aurolab, India [324]: data by Marc Phelan MD, Abilene, TX, USA Curamed PL 600 A=118.8 a0=0.209 a1=0.124 a2=0.182 pACD=5.46 sf=1.68 A=118.8 A=119.0 180 [218],[219] Bausch&Lomb BL27 A=117.8 a0=1.16 a1=0.40 a2=0.10 pACD=5.31 sf=1.55 A=118.6 A=119.0 96 [30] [37]: data by F.C.Nickel, MD, Peine, Germany [97]: data by Asim Piracha, MD, West Mifflin, PA, USA ARGONOPTICS EUROMAXX A=118.0 a0=0.87 a1=0.40 a2=0.10 pACD=5.09 sf=1.33 A=118.2 A=118.5 105 [43] [3]: based on data by J.L.Parisi MD, Clemson SC, USA and Harvey K.Minatoya MD, Honolulu, HI, USA [139]: data by Dr.C.Deman, Koksijde, Belgium [294]: data by Prof. Mark Packer MD, Eugene, OR, USA [333]: data by Dr. Alfredo Ferrer, Denia, Spain [330]: data by Dr. Gilles Lesieur, Albi, France [75]: data by Dr.U.Heuer, Hamburg, Germany A=118.1 a0=1.53 a1=0.40 a2=0.10 pACD=5.75 sf=1.96 A=119.2 A=119.6 68 [53] Corneal 600SE A=119.5 a0=2.26 a1=0.40 a2=0.10 pACD=6.43 sf=2.65 A=120.3 A=121.1 51 [12] [325]: data by Dr. Julio Fernandez Mendy, Buenos Aires, Argentina Disclaimer. J Cataract Refract Surg. [304]: data by Dr.H.Kaymak, Dr.D.Breyer, Dsseldorf, Germany Alcon AcrySof MA60BM A=118.9 a0=1.443 a1=0.077 a2=0.163 pACD=6.08 sf=2.33 A=119.8 A=120.4 271 [2],[10],[18] INDICATION: The ClareonAspheric Hydrophobic Acrylic IOLs include the Clareon Aspheric and Clareon Aspheric Toric IOLs and are indicated for primary implantation in the capsular bag in the posterior chamber of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. [63]: data by Dr.C.Binder, Schramberg, Germany [22]: data by A.Heine, MD, Rostock, Germany [162]: data by Dr.L.Frisch, Wiesbaden, Germany [336]: data by Dr. Jean Philippe Seguin, Nevers, France Haigis, Graefes Arch Clin Exp Ophthalmol (2000) 238:765-773 Polytech Polylens A62 (+) A=118.2 a0=1.15 a1=0.40 a2=0.10 pACD=5.35 sf=1.58 A=118.6 A=118.9 141 [93],[94] An Nd:YAG laser posterior capsulotomy was performed in 0.64% (13/2044) in the SA30AL group over a mean of 9 months (range 2 to 23 months) and in 0.34% (2/586) in the SA60AL group over a mean of 5.5 months (range 5 to 6 months). IOL nominal Haigis HofferQ Holl.1 SRK/T SRK II n Ref. [370]: data by Mr. Azfar W. Chohan, Isle of Man [145]: data by Dr.T.Haldimann, Bern, Schweiz [97]: data by Asim Piracha, MD, West Mifflin, PA, USA Alcon Toric SN6AT(3-5) (Japan)A=119.0 a0= 1.78 a1=0.40 a2=0.10 pACD=5.91 sf=2.08 A=119.3 A=119.6 77 [41] [78]: data by Prof.Dr.Th.Neuhann, Mnchen, Germany Aaren Scientific EC-3 PAL A=117.7 a0=1.10 a1=0.40 a2=0.10 pACD=5.28 sf=1.46 A=118.4 A=118.4 47 [365] Alcon, a Novartis Division. The ratio of the focal length of a digital camera lens to a 35mm still camera lens. [72]: data by Dr.W.Htz, Bad Hersfeld, Germany We partner with industry leaders in both technology and healthcare worlds to offer a quick guide that will help to find the most needed solutions for your patient needs. [276]: data by Dra. [123]: data by Dr.J.Bosche, Diepholz, Germany The remaining . Physiol PodEye A=118.9 a0=1.70 a1=0.40 a2=0.10 pACD=5.85 sf=2.06 A=119.4 A=119.8 71 [351] [142]: data by Dr.J.Bauer, Mainz, Germany [55]: data by W.Hill, MD, USA [368]: data by Dr. Martin Bechmann, Mnchen, Germany [338]: data by Dr. Ruth Lapid-Gortzak, Driebergen, The Netherlands Polytech Polylens AS61 A=118.2 a0= -2.993 a1=0.189 a2=0.294 pACD=5.00 sf=1.24 A=118.1 A=118.3 429 [315] [387]: data by Dr. BAE Gye Jong, Incheon, South Korea HumanOptics Diff-aA(Y) A=118.4 a0=1.28 a1=0.40 a2=0.10 pACD=5.50 sf=1.73 A=118.9 A=119.2 87 [155],[36 Alcon AcrySof MA60AC A=118.4 a0= 0.229 a1=0.011 a2=0.205 pACD=5.67 sf=1.90 A=119.2 A=119.5 399 [18],[114],[150],[171] [151]: data by Dr.Lebrun, France [349]: data by Dr.Dhaval S. Modi, Ahmedabad, India [382]: data by Dr. KIM Joon Hyun, Seoul, South Korea Nidek Nex-Acri AA A=119.5 a0=1.56 a1=0.40 a2=0.10 pACD=5.73 sf=1.95 A=119.2 A=119.7 167 [18] [396]: data by Dr. A. Liermann, Neustadt / Weinstrasse, Germany We believe that effective technology can bring big improvement to healthcare management and patient management. Keith A.Gross MD, New Zealand, [233]: data by Dr.R.Schmid, Dillingen, Germany [8]: based on data by L.Fry, MD, Garden City, KS, USA Nidek Nex-Acri A=118.8 a0=1.55 a1=0.40 a2=0.10 pACD=5.74 sf=1.95 A=119.2 A=119.5 72 [62],[63],[18] The single-piece acrylic lenses performed well in all regards. [301]: data by Prof. Dr. V.Jasinskas, Kaunas, Lithuania Polytech Aurium 404 A=118.3 a0=1.57 a1=0.40 a2=0.10 pACD=5.78 sf=2.01 A=119.3 A=119.5 50 [373] Staar KS-SP (Japan) A=119.1 a0=0.943 a1=0.243 a2=0.161 pACD=6.00 sf=2.18 A=119.5 A=119.8 207 [41] [3]: based on data by J.L.Parisi MD, Clemson SC, USA and Harvey K.Minatoya MD, Honolulu, HI, USA [298]: data by Dr. L. Bauer, Bremen The device is for single use only. [264]: data by Dr. C.Niederdellmann, Friedberg, Germany [381]: data by Dr. KIM Joung Mok, Seoul, South Korea [165]: data by Dr.R.Friedrich, Meiningen, Germany Krmer, Domeier und Pache, Lbeck, Germany Oculentis L-402 A=118.0 a0= -1.204 a1=0.103 a2=0.230 pACD=5.05 sf=1.30 A=118.2 A=118.5 618 [106],[120] The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Soleko FIL611 A=118.5 a0=0.051 a1=0.140 a2=0.197 pACD=5.68 sf=1.90 A=119.1 A=119.2 259 [360] Polytech Polylens S80 A=117.8 a0=0.49 a1=0.40 a2=0.10 pACD=4.68 sf=0.90 A=117.5 A=117.6 155 [22],[25] [17]: data by J.Brndle, MD, Fssen, Germany [108]: data by Dr.R.Zimmer, Lbau, Germany PMC [268]: data by Dr. F.Kesteloot, Kortrijk, Belgium HumanOptics MC611MI discontinued A=118.3 a0=1.59 a1=0.40 a2=0.10 pACD=5.85 sf=2.08 A=119.4 A=119.8 66 [70] South Korea ZEISS TS43 - discontinued A=118.5 a0=1.13 a1=0.40 a2=0.10 pACD=5.19 sf=1.43 A=118.4 A=118.7 13 [6] Setting: [393]: data by Dres Becker, Cordero, Maruniak. Dr.Schmidt MP2125 A=118.2 a0=1.34 a1=0.40 a2=0.10 pACD=5.57 sf=1.79 A=119.0 A=119.0 107 [47],[48],[49] SA60AT - Model SA60AT AcrySof Single-Piece Posterior Chamber Intraocular Lenses, UV-Absorbing, Acrylic Foldable - Alcon AU00T0 AcrySof IQ Ashperic Posterior Chamber with UltraSert IOL IFU . Domilens Nex-Load Preloaded A=119.2 a0=1.73 a1=0.40 a2=0.10 pACD=5.87 sf=2.11 A=119.5 A=120.0 98 [222] Curamed HD60CZ-YA A=118.4 a0=1.30 a1=0.40 a2=0.10 pACD=5.50 sf=1.72 A=118.9 A=119.2 127 [391] [55]: data by W.Hill, MD, USA [80]: data by Dr. Kazuya Yamagishi, Japan Results: [342]: data by Dr. Sri Ganesh, Bangalore,India biometry and partial coherence interferometry for IOL calculation according to . [119]: data by Prof.Dr.R.Welt, Ludwigshafen, Germany [313]: data by Dr.J.Burger, Deggendorf, Germany Out of stock. Oculentis L-402-1 discontinued A=118.0 a0= 1.58 a1=0.40 a2=0.10 pACD=5.75 sf=1.97 A=119.2 A=119.5 9 [106] That is from this all lenses above this model are biconvex in design. [163]: data by Dr.H.Hofmann, Schaffhausen, Switzerland [54]: data by Dr.A.Gross, Burghausen, Germany Below are lens constants for popular IOLs to be used with the Hill-RBF calculator. [373]: data by Dr. Edith Krehn, Bayreuth, Germany [133]: data by Keith Kellum, MD, Houma, LA, USA [279]: data by Vista Klinik Binningen, Switzerland [262]: data by Dr. J.Novak, Pardurbice, Czech Republic [228]: data by Dr.R.v.Horenbeeck, Antwerpen, Belgium [164]: data by Dr.U.Berens, Karlsruhe, Germany ACRYSOF Aspheric UV Absorbing ReSTOR +2.5 D Toric IOL, ACRYSOF IQ RESTOR +2.5 D Multifocal Toric IOL, ACRYSOF IQ RESTOR +3.0 D Multifocal Toric IOL, ACRYSOF MultiPiece - Posterior Convex IOL & EXPAND Series IOLs, AIR OPTIX AQUA Multifocal Contact Lenses, AIR OPTIX for Astigmatism Contact Lenses, AIR OPTIX NIGHT & DAY AQUA Contact Lenses, AIR OPTIX plus HydraGlyde Contact Lenses, AIR OPTIX plus HydraGlyde for Astigmatism Contact Lenses, AIR OPTIX plus HydraGlyde Multifocal Contact Lenses, (proparacaine hydrochloride ophthalmic solution, USP) 0.5%, Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL. [92]: data by Prof.Dr.G.U.Auffarth, Heidelberg, Germany (For details how to create your own tentative constants, [398]: data by Dres. AdShop Our Huge Selection Of Alcon Eye Care Products & More Today! ALCON SA60AT Intraocular Lens 25.0D, Length 13.0mm, Optic 6.00mm SRK/T Optical A-Constant : 118.7 SRK/T Ultrasound A-Constant :118.3 All items listed are on inventory. [105]: data by Wavelight AG, Berlin, Germany Hoya AF-1 YA-60BBR Hoya iSert PY-60R (+) A=118.4 a0=1.06 a1=0.40 a2=0.10 pACD=5.24 sf=1.48 A=118.5 A=118.8 134 [81],[149] Epub 2008 Apr 19. Oculentis L-450 A=118.2 a0= 1.30 a1=0.40 a2=0.10 pACD=5.42 sf=1.67 A=118.8 A=119.2 27 [106] 2019;45:1490-1497. Alcon Panoptix TFNT00 A=119.1 a0=1.39 a1=0.40 a2=0.10 pACD=5.63 sf=1.83 A=119.1 A=119.3 26 [395] [390]: data by Dr. C. Kloos & Dr. B. Pleisch, Augenzentrum Wil, Switzerland . Polytech Polylens H11(Y11) (+) A=118.3 a0= -0.037 a1=0.032 a2=0.214 pACD=5.67 sf=1.90 A=119.1 A=119.3 253 [287],[361],[220],[317] Canon AQ-310AI (Japan) A=119.5 a0=2.17 a1=0.40 a2=0.10 pACD=6.32 sf=2.52 A=120.1 A=120.7 68 [26] [135]: data by B.Shingleton, MD, Boston, MA, USA FOIA Objective: To compare the visual performance of aspherical AcrySof IQ (SN60WF) and SA60AT spherical intraocular lenses after cataract surgery. [202]: data by M.Franke, Kirchberg, Germany Careful preoperative evaluation and sound clinical judgment should be used by the surgeon to decide the risk/benefit ratio before implanting the IOL in a patient with any of the conditions described in the Directions for Use. [120]: data by Dr.L.Tschernjakov, Berlin, Germany [15]: data by J.Chvojkova, MD, Prague, Czech Republic After surgery, physicians should provide an implant card to patients regarding the IOL implanted. Europe / Middle East / Africa HumanOptics 1CU discontinued A=118.1 a0=1.833 a1=0.225 a2=0.094 pACD=5.38 sf=1.61 A=118.7 A=119.0 268 [9],[33] AMO SI40 NB A=118.0 a0= -0.199 a1=0.276 a2=0.169 pACD=5.19 sf=1.42 A=118.4 A=118.6 1172 [2],[17],[18] [85]: data by O.Hauptman, MD, Australia Werner L, Thatthamla I, Ong M, et al. [132]: data by C.Lackerbauer, Mnchen, Germany Alcon SA60AT AcrySof Single-Piece Acrylic Foldable IOL, UV-Absorbing Posterior Chamber Lens, 13.0mm Length, 6.0mm Biconvex Optic, Planar Haptics Item Past Expiration 033310/2 Features Condition: New Country of origin : United States Ships From : United States Brand Product Brand: Alcon 4.00 Average star rating 1 review 5 Stars 0 4 Stars 1 3 Stars 0 Schindler, Klaessen, Sendtner, Ingolstadt, Germany C.Wehner MD(Bremervrde, Germany), [81]: data by Dr.T.Laube, Duesseldorf, Germany Optic glistenings were observed in 11 (11%) of 100 SA30AL cases at a mean follow-up of 8 months. different surgeons from Eye Clinic Kln-Merheim, Germany
Ethan Couch Family Net Worth, Estero High Assistant Principal, Articles A